If you have sensors installed MilkHub is able to monitor temperature and water flow to ensure every bail is cleaned properly after every milking. Cold cycles must have enough water flow to be correctly cleaned, and hot cycles must also be hot enough to kill bacteria.

The report shows information from a single cleaning after milking:


Image

1. Hover over highlighted bails to see alert details.
2. Click Want to See More to see full details from every bail.
3. Highlighted bails should have their jetters and pipework checked.

Image The hot cycle temperature must reach a minimum of 65C. Throughout the plant, this means the reservoir temperature needs to be higher to allow for temperature drop as it flows through the pipes.

The default settings for the Cleaning Report are set to a high threshold. If you have many more bails alerting than you believe there should be you can adjust the Sensitivity Settings, however we emphatically recommend the hot cycle threshold is not set below 65 degrees.
Cleaning Report Sensitivity Settings